CV Elite – Coarctation Clamp – Cooley Jaws
CV Elite – Coarctation Clamp – Cooley Jaws
cooley jaws, 4.0 cm straight jaws, 6-3/4″ (17.0 cm)
Coarctation Clamp is a clamp used for a variety of cardiovascular surgical procedures. It has long DeBakey jaws for exceptional reach and grip in the surgical field without causing unwanted trauma. The clamp is made in Germany by expert instrument manufacturers from operating room quality stainless steel, which is polished to a dull satin finish to minimize glare.
SKU:
ESI-04-1047
Category: Cardiovascular Clamps
Description
| Name | CV Elite – Coarctation Clamp – Debakey Jaws |
| Lead Time | LEAD TIME ADVISED WITHIN 48 HOURS OF ORDER PLACEMENT. |
| Specialty | Cardiothoracic-Clamps-Stainless Vascular Clamps – Standard Clamps |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | Euro Site Industries |
| Sterility | Non-Sterile |
| Usage | Reusable |
Reviews (0)
Be the first to review “CV Elite – Coarctation Clamp – Cooley Jaws” Cancel reply
Shipping & Delivery
Related products
Bailey Aorta Clamp
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Cooley Acutely Curved Clamp
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Caval Occlusion Forceps
Cooley Caval Occlusion Forceps
8-1/4" (21.0 cm)
Cooley Caval Occlusion Forceps are specially designed vascular clamps for use in cardiothoracic surgical procedures. This instrument is designed with ring handles for ease in maneuvering and opening and closing and also a ratcheting mechanism to hold the forceps at a particular tightness. The most unique feature of these forceps is that each jaw features a half circle projection outwards which when the jaw is brought together forms a complete circular opening as well as the fact that the entire instrument is formed in a crescent type shape. This instrument is available with a number of different diameters to the opening in the jaws in 2 fr. Increments from 24 – 40 fr.
Cooley Multi Purpose Clamp
Cooley Multi Purpose Clamp
jaws angled 60 degrees
Cooley Multi Purpose Clamp is designed for use in a variety of cardiothoracic surgeries that require clamping of vessels. These multi-purpose clamps are uniquely designed to accommodate a number of different surgical maneuvers instead of being made for one specific purpose. The multiple application of this instrument making it a valuable tool in the operating room because it is suitable for most all clamping situations. Additionally, the jaws come angled at 60 degrees and this instrument is available in three different jaw lengths making it easy to find a suitable instrument for any surgical maneuver or surgeon preferences.
Cooley Occlusion Clamp
Cooley Occlusion Clamp
curved jaws, jaws 3.6 cm long
Cooley Occlusion Clamp is designed for use in cardiothoracic surgical procedures. This clamp can be used to clamp vessels to reduce or stop blood flow to prevent the patient from losing an excessive amount of blood. The jaws allow for firm grasp of the vessels but with reduced risk of crushing or bruising to the vessel wall. Additionally, this clamp features curved shanks and jaws giving them a contour more suitable for use in vascular surgical procedures. This instrument is available in two different lengths to accommodate different vessel sizes and positions.
Cooley Pediatric Clamp
Cooley Pediatric Clamp
delicate clamp, jaws calibrated at 5.0 mm intervals, 5-1/2" (14.0 cm)
Cooley Pediatric Clamp is ideally suited for clamping in cardiothoracic surgical procedures with pediatric patients. This clamp features jaws that are calibrated at 5.0 mm intervals but are still delicate enough for use in pediatric surgeries. This instrument is designed to keep a firm hold on the vessels that are being occluded but delicate enough not to bruise or tear the vessels thus reducing the amount of damage done to the patient. This clamp is available in a number of different styles that include straight or angled shanks and straight, satinsky, angled, or spoon-shaped jaws making this instrument highly versatile and useful in the operating room.
Exclusion Clamp
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.

Reviews
There are no reviews yet.