Cooley Coarctation Clamp – 9 3/4″
Cooley Coarctation Clamp – 9 3/4″
7.0 cm long straight jaws, straight shanks, 9-3/4″ (24.8 cm)
Cooley Coractation Clamp is well suited for use in cardiothoracic surgical procedures that necessitate total or partial occlusion of a vessel. This is often done in cardiothoracic surgical procedures to prevent the patients from losing an excessive amount of blood during surgery. This pattern features longer jaws and a longer overall length for cases where additional reach is necessary, as well as straight jaws and shanks which are designed to provide a firm and stable grip once they have been affixed to the site where the clamping is needed.
SKU:
ESI-04-1023
Category: Cardiovascular Clamps
Description
| Name | Cooley Coarctation Clamp – 9 3/4″ |
| Lead Time | Lead time advised within 48 hours of order placement. |
| Specialty | Cardiothoracic-Cardiovascular Clamps |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | Euro Site Industries |
| Sterility | Non-Sterile |
| Usage | Reusable |
Reviews (0)
Be the first to review “Cooley Coarctation Clamp – 9 3/4″” Cancel reply
Shipping & Delivery
Related products
Bailey Aorta Clamp
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Cooley Anastomosis Clamp Modified
Anastomosis Clamp Modified
30 degree side angled jaws, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp Modified is ideally used in cardiothoracic surgeries that require anastomosis between vessels and thus a clamp is utilized to reduce but not completely occlude blood flow. This instrument is hand-crafted by certified instrument makers to conform to the highest standards in instrumentation. Additionally, this modified anastomosis clamp features a 30 degree side angled jaw making it more able to access harder to reach vessels.
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Cardiovascular Clamp – Fully-Curved
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Cooley Miniature Multi Purpose Clamp
Cooley Miniature Multi Purpose Clamp
jaws calibrated at 5.0 mm intervals.
Cooley Miniature Multi Purpose Clamp is well suited for a variety of uses in cardiothoracic surgical procedures. Although this instrument does not have one particularly function but instead is a multi purpose clamp that can be used in a variety of different instances. The miniature size of this clamp makes it more able to reach certain vessels but also makes it better suited for use in smaller patients. This clamp comes equipped with jaws calibrated at 5 mm intervals and is available in three different angles 30, 60 and 90 degrees.
Cooley Neonatal Clamp
Cooley Neonatal Clamp
5" (12.5 cm)
Cooley Neonatal Clamp is the ideal tool for use in surgical procedures for newborn children. This clamp is build sturdily but made small enough to clamp the delicate vessels of a newborn child. This instrument is particularly well suited due to its ability to maintain a hold on the vessel without causing tears or rip on the delicate vessel walls of the newborn. Additionally, this clamp is available in a straight profile, spoon jawed, anastomosis clamp, carotid clamp or angled shank and straight jaws or curved shanks and angled jaws.
Cooley Occlusion Clamp
Cooley Occlusion Clamp
curved jaws, jaws 3.6 cm long
Cooley Occlusion Clamp is designed for use in cardiothoracic surgical procedures. This clamp can be used to clamp vessels to reduce or stop blood flow to prevent the patient from losing an excessive amount of blood. The jaws allow for firm grasp of the vessels but with reduced risk of crushing or bruising to the vessel wall. Additionally, this clamp features curved shanks and jaws giving them a contour more suitable for use in vascular surgical procedures. This instrument is available in two different lengths to accommodate different vessel sizes and positions.
Cooley Tangential Occlusion Clamp
Cooley Tangential Occlusion Clamp
double angled jaws calibrated at 5.0 mm intervals, 7-3/4" (19.5 cm)
Cooley Tangential Occlusion Clamp is uniquely designed to clamp vessels in a way that reduces blood flow without completely stopping it in cardiothoracic surgical procedures. This clamp can be best used when doing procedures such as side-by-side anastomosis that required some blood flow. Additionally, this instrument features double angled jaws that are calibrated at 5 mm intervals making it possible to make accurate measurements during the procedure.

Reviews
There are no reviews yet.