Hirschman Iris Hook
0.75 mm hook, angled, 4-3/4″ (12.0 cm) Hirschman Iris Hook is a commonly used tool during cataract procedures and operations needing access to the lens capsule. The 0.75mm hook provides fine control while retracting only a selected portion of iris tissue. A blunted tip assures minimal tissue damage to the surrounding globe.
SKU:
WI-3731
Category: Hooks &Manipulators
Description
| Name | Hirschman Iris Hook |
| Lead Time | Lead time advised within 48 hours of order placement. |
| Competitor | ;OP2502;350349;350-349;601326;60-1326;E0549H;6013-26; |
| Specialty | Ophthalmology-Hooks & Manipulators |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | Euro Site Industries |
| Sterility | Non-Sterile |
| Usage | Reusable |
Reviews (0)
Be the first to review “Hirschman Iris Hook” Cancel reply
Shipping & Delivery
Related products
Double Fixation Hook
5-1/4" (13.5 cm) Double Fixation Hook is a useful tool in ophthalmic and occuloplastic procedures. The instrument may be used to atraumatically fix the lid or other skin flaps for manipulation of deeper tissues. Two different hook widths are available depending on surgical preference and patient variation.
Green Strabismus Hook
flat handle, 5-1/8" (13.0 cm) Green Strabismus hook is a commonly used instrument in performing procedures involving the ocular muscles. The hook can be used to elevate the muscle tissue for dissection and reattachment. The toe of the hook is designed to press against the sclera and "ski" along the surface until the full muscle width has been discerned.
Harris-Sinskey Lens Manipulating Hook
0.25 mm diameter, blunt tip, angled Harris-Sinskey Lens Manipulating Hook is a useful tool in cataract procedures. The hook may be used to maneuver lens tissue in order to facilitate extraction of the opacified tissue. The smaller diameter hook affords the surgeon increased control during the procedure. In addition, the blunt tip ensures minimal tissue damage or posterior capsule tear.
Maloney No-Hole Iol Manipulator
tear drop shape tip w/ post, 4-3/4" (12.0 cm) Maloney No-Hole IOL Manipulator is a useful tool for cataract procedures. The tear-drop shaped tip is ideal for manipulating the lens implant without risk of damaging or scratching. The extended working length allows the surgeon to maneuver the implant into the space desired.
Maltzman-Fenzl Lens Manipulating Hook
0.15 mm v-shaped tip, 4-3/4" (12.0 cm) Maltzman-Fenzl Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The tip contains 2 prongs designed to cup the lens in a variety of positions. Both angled and straight models are available with the hook depending on surgical preference.
Nagahara Nucleus Chopper
1.25 mm tip & blade offset at 60 degree angle, round knurled handle, 4-1/2" (11.4 cm) Nagahara Nucleus Chopper is a commonly used tool in cataract extraction procedures. The chopper is used to divide the opacified nucleus into smaller pieces for eventual extraction. The instrument features a 1.25 mm tip with a 60 degree offset blade, aiding in visualization during incisions of lens tissue.
Sheets Iris Hook
0.3 mm hook w/ guard, 5-1/8" (13.0 cm) Sheets Iris Hook is a commonly used tool during cataract procedures and operations needing access to the lens capsule. The 0.3mm hook provides extra fine control in retracting only the desired portion of iris. In addition, the hook comes available with a guard to protect from damaging surrounding tissue.
Shepard Iris Hook
1.0 mm, blunt, 4-7/8" (12.4 cm) Shepard Iris Hook is a commonly used tool in cataract surgeries. The hook is used to retract a portion of the iris tissue to gain access to the lens capsule. Often, multiple hooks are used at different positions around the iris and anchored, providing adequate visualization for lens removal. The hook features a blunt tip to minimize extraneous tissue damage.

Reviews
There are no reviews yet.