CV Elite – Baby Vascular Clamp W/ Spoon Jaws
CV Elite – Baby Vascular Clamp W/ Spoon Jaws
cooley jaws
Baby Vascular Clamp with Spoon Jaws is used frequently in cardiothoracic operations on smaller patients or those where peripheral vessels must be clamped. The uniquely curved jaws allow for easy access to peripheral vessels, and the Cooley serration makes atraumatic occlusion of effortless. The clamp is manufactured in Germany from high quality stainless steel, and conforms to the highest standards of surgical instrumentation.
SKU:
ESI-04-1043
Category: Cardiovascular Clamps
Description
| Name | CV Elite – Baby Vascular Clamp W/ Spoon Jaws |
| Lead Time | LEAD TIME ADVISED WITHIN 48 HOURS OF ORDER PLACEMENT. |
| Specialty | Cardiothoracic-Clamps-Stainless Vascular Clamps – Delicate Clamps |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | Euro Site Industries |
| Sterility | Non-Sterile |
| Usage | Reusable |
Reviews (0)
Be the first to review “CV Elite – Baby Vascular Clamp W/ Spoon Jaws” Cancel reply
Shipping & Delivery
Related products
Bailey Aorta Clamp
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Cherry Supraceliac Clamp
Cherry Supraceliac Clamp
shanks curved 60 degrees, debakey 2x3 teeth, jaws 5-3/4", curved, 12-1/2" (31.0 cm)
Cheery Supraceliac Clamp is created to be of optimal use in cardiothoracic surgical procedures. This instrument is especially useful aortic aneurysm repairs of the abdominal and thoracic aorta particularly this clamp can be used in accessing the portion of the aorta that is found superior to the celiac artery. Curved shanks coupled with a 60 degree angle and DeBakey teeth allow this clamp to access some deeper vessel structures without damaging the vessel walls or the surrounding tissue.
Cooley Anastomosis Clamp
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Anastomosis Clamp Modified
Anastomosis Clamp Modified
30 degree side angled jaws, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp Modified is ideally used in cardiothoracic surgeries that require anastomosis between vessels and thus a clamp is utilized to reduce but not completely occlude blood flow. This instrument is hand-crafted by certified instrument makers to conform to the highest standards in instrumentation. Additionally, this modified anastomosis clamp features a 30 degree side angled jaw making it more able to access harder to reach vessels.
Cooley Iliac Clamp
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Miniature Multi Purpose Clamp
Cooley Miniature Multi Purpose Clamp
jaws calibrated at 5.0 mm intervals.
Cooley Miniature Multi Purpose Clamp is well suited for a variety of uses in cardiothoracic surgical procedures. Although this instrument does not have one particularly function but instead is a multi purpose clamp that can be used in a variety of different instances. The miniature size of this clamp makes it more able to reach certain vessels but also makes it better suited for use in smaller patients. This clamp comes equipped with jaws calibrated at 5 mm intervals and is available in three different angles 30, 60 and 90 degrees.
Cooley Pediatric Clamp
Cooley Pediatric Clamp
delicate clamp, jaws calibrated at 5.0 mm intervals, 5-1/2" (14.0 cm)
Cooley Pediatric Clamp is ideally suited for clamping in cardiothoracic surgical procedures with pediatric patients. This clamp features jaws that are calibrated at 5.0 mm intervals but are still delicate enough for use in pediatric surgeries. This instrument is designed to keep a firm hold on the vessels that are being occluded but delicate enough not to bruise or tear the vessels thus reducing the amount of damage done to the patient. This clamp is available in a number of different styles that include straight or angled shanks and straight, satinsky, angled, or spoon-shaped jaws making this instrument highly versatile and useful in the operating room.
Exclusion Clamp
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.

Reviews
There are no reviews yet.